• Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical

Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical

Xinhong Electrical supplies three‑phase oil immersed distribution transformer in 100kVA,200kVA,315kVA with copper winding. ISO, CE, CB certified, IEC60076 standard, custom voltage available for power supply distribution projects.

Basic Parameter Table
Item Technical Parameter Product Type Three Phase Oil Immersed Distribution Transformer Rated Capacity 100kVA, 200kVA, 315kVA Standard Voltage Ratio 11kV/0.4kV (Customizable) Rated Frequency 50Hz / 60Hz Optional Winding Material Pure Copper (Aluminum Optional) Cooling Method ONAN (Oil Natural Air Natural) Connection Group Dyn11 (Standard) Executive Standard IEC60076 International Standard Certification ISO, CE, CB Certified
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical
  • Three Phase Oil Immersed Distribution Transformer 100kVA 200kVA 315kVA Copper Winding | Xinhong Electrical

Description

Our three‑phase oil immersed distribution transformer
100kVA, 200kVA and 315kVA is a proven workhorse for outdoor and indoor power supply distribution networks, manufactured by Xinhong Electrical in China. Built with high‑quality copper winding, this oil‑type electrical transformer delivers stable voltage conversion, low operating loss and long service life for utility, industrial, commercial and residential power projects.


Key Features of Copper Winding Oil Immersed Transformer

  • Pure copper winding: Excellent electrical conductivity, lower heat generation and strong short-circuit resistance, greatly improving reliability under continuous heavy-load operation.
  • High-grade silicon-steel core: Optimized core structure cuts no-load loss and running noise, achieving good energy-saving performance.
  • ONAN oil natural air natural cooling: Transformer oil works as both insulation and cooling medium, suitable for long-term outdoor operation.
  • Fully sealed tank construction: Corrosion-resistant paint treatment effectively prevents moisture and dust ingress, adapting to humid, dusty and coastal working conditions.
  • Complete safety accessories: Equipped with pressure relief valve, oil-level indicator and temperature monitoring device to ensure safe daily operation.
  • Strict international compliance: Manufactured in accordance with IEC60076 standards and certified with ISO, CE and CB, fully meeting global distribution transformer application requirements.

Main Technical Scope

Available capacities: 100kVA, 200kVA, 315kVA three-phase oil immersed distribution transformer
Standard voltage: 10kV / 0.4kV; custom 6kV, 11kV, 20kV, 35kV voltage classes are acceptable
Frequency: 50Hz / 60Hz optional
Connection group: Dyn11 as standard
Winding material: Copper winding (aluminum winding is optional upon request)

Typical Applications

This oil immersed power distribution transformer is widely applied for power grid reconstruction, factory power supply, mining sites, commercial buildings, rural electrification projects and renewable energy auxiliary power distribution systems. It is the preferred oil-type electrical transformer for medium-voltage power transmission and step-down tasks.

About Xinhong Electrical

As a professional Chinese manufacturer of oil immersed distribution transformers, Xinhong Electrical provides full-set solutions including drawing review, parameter customization, factory test reports and complete export documentation. We support bulk orders and project tender cooperation. Contact our engineering team for detailed quotations and technical datasheets of 100kVA-25000kVA copper winding oil immersed transformers.

Download