Categoría

S13 / S20 Oil Immersed Transformer: Efficiency, Loss Comparison

Nov 3rd,2026 10 Puntos de vista

Intro

When selecting oil immersed distribution transformers for industrial, commercial, grid and renewable energy projects, efficiency and loss performance directly decide long-term operational expenditure. S13 and S20 are two mainstream fully sealed oil-immersed transformer series widely supplied by Chinese transformer factories. Many buyers struggle to tell the difference between S13 and S20, including loss gap, energy saving rate, payback period and suitable application scenarios.

In this guide from Xinhong Electrical, we make a clear comparison of efficiency, no-load loss and load loss between S13 and S20 oil immersed transformers, help you pick the right model for your budget and load profile. All our S13 and S20 transformers adopt pure copper winding, high-grade grain-oriented silicon steel, fully sealed corrugated tank structure, with ISO9001, CE and CB certifications, complying with IEC 60076 and GB 20052 energy efficiency standards.

What Are S13 and S20 Oil Immersed Transformers?

S13 and S20 are low-loss three-phase oil immersed distribution transformers for 10kV / 20kV class power distribution systems, with capacity range from 30kVA up to 2500kVA.

  • S13 Oil Immersed Transformer: 3rd energy efficiency level, mature mass production model, stable supply and competitive upfront price. It is a cost-effective baseline energy-saving transformer widely used in residential districts, small factories and projects with low annual running hours.
  • S20 Oil Immersed Transformer: Higher 2nd energy efficiency level, upgraded core design with premium Hi-B silicon steel sheet. It cuts both no-load loss and load loss significantly, built for projects with long continuous operation, high electricity consumption and strict carbon reduction requirements.

Xinhong Electrical manufactures both S13 and S20 oil immersed transformers in our factory in Jiangsu, China. All units are 100% full copper winding, factory tested before delivery.

Core Loss & Efficiency Comparison (S13 VS S20)

No-load loss and load loss are the two critical parameters to judge transformer efficiency. No-load loss runs continuously once energized, while load loss changes with actual load rate.

Take 1000kVA 10kV oil immersed transformer as the benchmark reference:

  • S13: No-load loss 0.83kW, Load loss 10.3kW
  • S20: No-load loss 0.745kW, Load loss 8.24kW

Compared with S13, S20 oil immersed transformer reduces no-load loss by around 10% and load loss by nearly 20%. The overall energy efficiency of S20 is higher, which brings obvious electricity saving for long-running equipment.

Efficiency Curve Difference

  • S13 reaches its optimal efficiency around 60%~75% load rate. It works well for intermittent load, daytime-only production lines.
  • S20 maintains ultra-high efficiency on a wider load band (40%~85%). It is more suitable for 24h continuous load, data center, solar/wind power station, heavy industrial park.

Key Pros & Cons

H3: S13 Oil Immersed Transformer

✅ Advantages

  • Lower initial purchasing cost
  • Stable, proven design, easy spare parts sourcing
  • Good choice for short running hours, low budget distribution projects ❌ Limitations
  • Higher no-load and load loss vs S20
  • Higher annual electricity cost for continuous operation

H3: S20 Oil Immersed Transformer

✅ Advantages

  • Lower no-load & load loss, higher energy efficiency
  • Shorter investment payback cycle for long-operation scenarios
  • Meets strict energy saving, carbon emission reduction and green grid requirements
  • Lower heat generation, slower insulation aging, longer service life ❌ Limitations
  • Higher upfront factory price
  • Higher requirement on raw material and core processing

How to Choose Between S13 and S20?

You can make the decision based on 3 core factors: annual operating hours, local electricity price and project tender energy requirement.

  1. Choose S13: If your transformer runs less than 8–10 hours per day, small commercial power supply, low budget, low load duration.
  2. Choose S20: If the transformer runs 16–24 hours daily, industrial plant, solar farm, substation, EPC tender with mandatory high energy efficiency rules.

If you are not sure which model fits your project, send your required kVA, voltage ratio and daily load hours to Xinhong Electrical. Our engineering team can provide loss calculation and TCO analysis for free.

Xinhong Electrical S13 & S20 Oil Immersed Transformer Features

As a professional oil immersed transformer manufacturer based in China, Xinhong Electrical supplies S13, S20 and S22 series fully sealed oil transformers for global markets:

  • Pure copper winding, low resistance, strong short-circuit withstand capability
  • High permeability grain oriented silicon steel core, optimized stacking process
  • Corrugated radiator tank, maintenance-free, no conservator required
  • Low noise, anti-corrosion, suitable for outdoor installation
  • Available with off-circuit tap changer, on-load tap changer option
  • Certificates: ISO9001, CE, CB, test reports per IEC60076
  • Capacity range: 30kVA ~ 25MVA, 6kV / 10kV / 20kV / 35kV available

FAQ

Q1: Does S20 transformer always save money than S13?

A1: Not always. The saving effect depends on running hours and electricity price. For short-time use, S13’s lower initial cost is more economical. For 24h continuous load, S20 will recover the extra investment within 2–4 years.

Q2: Can Xinhong Electrical customize S13 / S20 oil immersed transformer?

A2: Yes. We support custom voltage ratio, vector group, protection accessories and paint color for overseas EPC projects.

Q3: What is the service life of S13 and S20 oil transformers?

A3: Under normal operating conditions, both models can reach 30+ years service life. S20 runs cooler due to lower loss, so its aging speed is slower.

Q4: Do you supply dry type transformer together with oil immersed transformer?

A4: Yes. Xinhong Electrical also provides dry transformer china, box type substation, RMU and other power distribution equipment.

Conclusion

S13 and S20 oil immersed transformers are both reliable energy-saving distribution transformers, but positioned for different efficiency tiers. S13 is the cost-effective baseline option, while S20 is the high-efficiency upgrade for heavy continuous load.

Before placing the order, calculate total loss and annual power consumption instead of only comparing ex-factory price. If you need quotation, loss sheet or technical datasheet for S13 or S20 oil immersed transformer, contact Xinhong Electrical, China professional transformer manufacturer.